mode. A binary input is defined which, when closed, sets the occupied status On causing the system to operate in the occupied mode. When the binary input is open, the system operates in the unoccupied mode. Table 3 Lab Occupancy Sensor Name Type Function Default Lab Occupancy Sensor BI-3 Hardwired Open off

Binary Input - Analog Input - Binary Output - Analog Output. The Binary input logic block will get an input signal of either on or off 0 or 1 in Binary speak from a device wired to the DDC controller. It will send an appropriate response out through other logic blocks for program processing through other logic blocks and eventually end

This number feeds into the PID logic block along with the static pressure setpoint and the input from another line of logic for fan status which is a binary input. The PID logic block processes the input it receives and makes a calculation for the necessary amount of output for the supply fan VFD. It sends this output to the next logic block.

Pumps, fans, compressors are onoff. Good as a binary input to read the status of these, or as an output to command these things to do something. Also an alarm is either alarm or normal, or activeinactive, so you could read a fire alarm input on a Binary Input. Analogs have a mumerical value, not a 2 state binary value.

ObjectsBinary Output BO Object 3 Introduction A Binary Output BO is the software representation of a 2-state onoff controlled device. The primary function of a binary output is to command Heating, Ventilation, and Air Conditioning HVAC and other equipment to an on or off state. A secondary function is to command external

DDC system binary output. c. Action Confirm water in cooling-tower sump. 2. Enable When outdoor-air temperature conditions are met a. Input Device Space thermostat DDC system outdoor-air temperature. b. Output Device Hard wired through motor starter DDC system binary output. c. Action Confirm outdoor-air temperature is above 50

A space-conditioning air-conditioning system fan-coil system Source Wang, S. K., Lavan, Z. and Norton, P., 2000. Air Conditioning and Refrigeration Engineering Air side Refrigeration AO Analogue output BI Binary Digital input BO Binary Digital output AV Analogue value BV Binary value Sched Schedule Trend Trend log. An

Universal Input UI This type of input can handle multiple signals. It can be configured for thermistors, modulating 0-10Vdc or it can be a binary contact. Digital or Binary Output DOBO This type of output is used with OnOff signals and stage control. It can be configured for heating andor cooling but can also be

HVAC systems use some form of controls from the very basic to the very sophisticated BMS, Building Management Systems that can monitor and control everything from the HVAC system, lighting, fire systems, and security systems. A binary input or output device has two options, such as either onoff or startstop, while an analog device can

At the heart of a properly operating HVAC system is the layer of controls that keep the system operating as intended. If the controls aren't functioning properly then there will be a loss of occupant comfort and an increase in energy consumption. Binary Input Boiler Enabled quotONquot Binary Output Boiler Status Binary Input Boiler