visualize the 12-o'clock and 6-o'clock areas of the breast, and localize and evaluate milk of calcium. Lateral views are also alternatives for patients who cannot undergo imaging with the standard mediolateral oblique MLO view, such as patients in wheelchairs or on stretchers, patients with di!cult body habi-

A mnemonic to help remember breast lesion localization when given a set of mammograms in mediolateral oblique MLO and 90-degreetrue lateral mediolateral ML or lateromedial LM views to predict laterality is. muffins rise and lead falls This can help localize a finding on MLO during diagnostic mammography into the quadrant e.g. upper outer, even when the finding is not well-seen on

True CC Lat Med Lat Med Lateral roll CC Med rolled CC Lesion in top half breast Lesion in bottom half breast Top breast rolled med Lat Lat Breast in compression viewed from front quotMedial rolled CC vieW' 'Lateral rolled CC vieW' Top breast rolled lat

Quadrant and o'clock location Understand that MLO projections distinguish between superior upper and inferior lower quadrants. CC projections distinguish between lateral outer and medial inner quadrants. The four quadrants are used in mammography a clock face is used in ultrasound.

Normal old MLO and CC views are placed back to back above the new views. Clock face description of breast lesion locations. The clock face location of breast findings is described by imaging a clock on both the left and the right breast as the woman faces the examiner. Note that the outer portion of the breast on the right is at the 9-o

The line will cross on the CC view, the lesion it is along the course of this line. To know how far back from the nipple the lesion is, measure the distance from the nipple on the MLO view and then reproduce it on the CC view. 1 Fig. 10 . O' clock position of lesions . Described by Eklund, this method consists in

In summary Recognize MLO versus CC projections Understand that MLO projections discern superior upper versus inferior lower Understand that CC projections discern lateral outer versus medial inner The four quadrants are used in mammography clockface in sonography Understand the clockface is mirror image for lateral outer and medial inner

A single-page web utility that converts lesion coordinates from craniocaudal CC and mediolateral-oblique MLO mammographic views into a clock-face position, streamlining breast MRI and mammography reporting. Features. Select the breast side, mark the lesion on both CC and MLO canvases, and review the computed clock-face hour. Customization.

When evaluating breast findings, it is important to accurately identify their location. Findings in the breasts are described by their orientation on a clock face Figure 1. When deciding on the clock face location of a finding on mammography two standard mammographic views are used, the MLO mediolateral oblique and CC craniocaudal views.

MLO Mediolateral Oblique REMEMBER MULD--medial up a clock, lateral down a clock or Muffins rise, Lead falls. CC Craciocaudal View-From the nipple to the marker in the mammogram image, R CC, L CC, is lateral. From the nipple away from the marker is medial. You cannot know if the lesion is in the superior or inferior plane in the