Pulse Output Kwh Meter Wiring
Many meters have pulse outputs, examples include single phase and three phase electrical energy meters, Gas meters, Water meters. The pulse output may be a flashing LED or a switching relay usually solid state or both. In the case of an electricity meter, a pulse output corresponds to a defined amount of energy passing through the meter kWh
Usually 3 signals are wired, KWh, KVA and a timing pulse. 9. It is critical for that ESB Networks provide the KWh pulse rate 1 pulse 1 KWh, 1 pulse 0.1 KWh etc. for the installation. The pulse rate is dependent on the meter installed and the current transformers CTs connected to the meter and is therefore site dependant. 10.
Understanding the Energy Meter's Pulse Output Wiring the Pulse Output to a Data Logger Configuring the Data Logger for Pulse Counting Conclusion FAQ. The pulses show the energy use in Wh or 11000th kWh. You'll need to adjust the pulse weight, rate, and other settings in the data logger. Conclusion.
kWh pulse output indicator RS485 Activity Indicators - RX receive, TX transmit 3 Mounting 1. Make a cutout in the panel to fit in the device. wrong for the existing wiring. 3 Use a high accuracy multi-meter to check that the values are truly nonsensical. 9 Power Up Checklist B. After Power Up 1. Make sure that each LED segment lights up
Many revenue meters transmit kW usage through a pulse output from a dry contact output. To log the instant kW and totalize kWh simply connect the contact output to one of the 4 pulse inputs DI 1-4 on the GRIDlink. The GRIDlink will take the raw pulse count and multiply by the user specified pulse weight to allow reporting of instant kW and kWh.
The default DTS 310 meters indicated above are fitted with 1 x pulse output as standard. They are grouped together with a single 6 way pluggable terminal. Wiring the Digital Pulse Output The single digital output - marked quotOUT 3quot is pre-configured to function as a pulse corresponding to measured kWh. The default pulse rate is 1 Pulse per
Figure 4 EMPULSE Meter Wiring PULSE OUTPUT WIRING OPTIONS There are three typical installation configurations for wiring Pulse Output 1 and Pulse Output 2, as shown below. 51-500A 10 Whpulse 501-5000A 100 Whpulse 5000A 1 kWhpulse For alternative pulse scale settings, see the EMPULSE Series Meter User's Guide. EMPULSE Energy Meter
12 NETWORK SELECTION AND WIRING INPUT 13 APPLICATION OF PULSE OUTPUT 14 TYPICAL WIRING DIAGRAM 15 Documents Resources. 15.1 References Pulse output kWh pulse lt15 0.01 0.01 lt150 0.1 0.1 Pulse output from EM306A meter can be used as alarm generator or total energy controller by interfacing it with Pre-settable counter
A Form C output can be used as a Form A pulse by using only K and Y, or K and Z, and doubling the Form C pulse value. Form A pulse values are always double Form C pulse values. Example .024kwh for a 2-wire equivalent of the pulse value in Standard 1. KYZ Pulse initiators are Dry-Contact switches. This means that there is no internally applied
If a pulse meter has a multiplier of 10 pulseskWh, and a system records 150 pulses in an hour, the energy consumption can be calculated as Pulse output voltage can vary based on the metering equipment used. Many pulse outputs are quotvolt-freequot or quotdry contacts,quot where the pulse is produced by closing a circuit without voltage. Other